Product DescriptiongoogleHuman LR3 insulin-like Growth Factor-I (LR3IGF-I) was developed by GroPep Bioreagents(www.gropep.com) specifically for supplementation of mammalian cell culture to support the survival and proliferation of cells. It is engineered to have a higher biological potency than native IGF-I or IGF-II and has several advantages over recombinant insulin. Supplementation of cell cultures with LR3IGF-I at a much lower concentration results in equivalent or better productivity than supplementation with standard concentrations of insulin. LR3IGF-I is better able to stimulate the type I IGF receptor and thus induce a higher level of activation of intracellular signalling molecules, which are responsible for promoting cell survival by inhibition of apoptosis.
This LR3IGF-I Rapid ELISA kit combines GroPep's many years of expertise in the field of IGF research and Biosensis' newly established Rapid ELISA platform. This collaboration has resulted in the new LR3IGF-I Rapid ELISA kit, which provides for the sensitive, specific and reliable quantification of LR3IGF-I protein in less than 3 hours!
The ELISA kit consists of a complete set of reagents and pre-coated plate to allow immediate assay of LR3IGF-I in culture media. Included in the kit are mouse monoclonal anti- LR3IGF-I capture antibody pre-coated onto an ELISA plate, standard LR3IGF-I protein, a biotinylated anti- LR3IGF-I detection antibody and horseradish peroxidase (HRP)-conjugated streptavidin. The addition of a substrate (3,3',5,5'-tetramethylbenzidine, TMB) yields a colored reaction product which is directly proportional to the concentration of LR3IGF-I present in samples and the supplied protein standard.
This LR3IGF-I Rapid ELISA kit has been developed, optimized and validated to quantify LR3IGF-I protein in cell culture medium. It is likely to be used to measure LR3IGF-I in media and during downstream processing of media following a production cycle and is not intended for other use. This kit has been configured for research use only and is not to be used in diagnostic or clinical procedures.
Alternative NamesHuman LR3 insulin-like Growth Factor-I.
Application(s)ELISA
SpecificityHuman The assay is intended for quantification of LR_IGF-I. Cross-reaction with human IGF-I is 32%. Cross-reaction with human IGF-II is less than 0.01%.
Species ReactivityHuman
Immunogen DescriptionRecombinant LR3-IGF1 protein, made in E.coli
Range3.9 ng/mL - 200 ng/mL
SensitivityTypical limit of detection (LOD) for LR_IGF-I is 1 ng/mL determined as 150% of the blank value.
Product DescriptionHuman LR3 insulin-like Growth Factor-I (LR3IGF-I) was developed by GroPep Bioreagents(www.gropep.com) specifically for supplementation of mammalian cell culture to support the survival and proliferation of cells. It is engineered to have a higher biological potency than native IGF-I or IGF-II and has several advantages over recombinant insulin. Supplementation of cell cultures with LR3IGF-I at a much lower concentration results in equivalent or better productivity than supplementation with standard concentrations of insulin. LR3IGF-I is better able to stimulate the type I IGF receptor and thus induce a higher level of activation of intracellular signalling molecules, which are responsible for promoting cell survival by inhibition of apoptosis.
This LR3IGF-I Rapid ELISA kit combines GroPep's many years of expertise in the field of IGF research and Biosensis' newly established Rapid ELISA platform. This collaboration has resulted in the new LR3IGF-I Rapid ELISA kit, which provides for the sensitive, specific and reliable quantification of LR3IGF-I protein in less than 3 hours!
The ELISA kit consists of a complete set of reagents and pre-coated plate to allow immediate assay of LR3IGF-I in culture media. Included in the kit are mouse monoclonal anti- LR3IGF-I capture antibody pre-coated onto an ELISA plate, standard LR3IGF-I protein, a biotinylated anti- LR3IGF-I detection antibody and horseradish peroxidase (HRP)-conjugated streptavidin. The addition of a substrate (3,3',5,5'-tetramethylbenzidine, TMB) yields a colored reaction product which is directly proportional to the concentration of LR3IGF-I present in samples and the supplied protein standard.
This LR3IGF-I Rapid ELISA kit has been developed, optimized and validated to quantify LR3IGF-I protein in cell culture medium. It is likely to be used to measure LR3IGF-I in media and during downstream processing of media following a production cycle and is not intended for other use. This kit has been configured for research use only and is not to be used in diagnostic or clinical procedures.
Application(s)ELISA
Application DetailsELISA. For the quantification of LR3IGF-I in Culture Supernatant. Please download the detailed product insert for complete instructions for the successful use of this ELISA. Use only as directed.
TargetLR3IGF-I
SpecificityHuman The assay is intended for quantification of LR_IGF-I. Cross-reaction with human IGF-I is 32%. Cross-reaction with human IGF-II is less than 0.01%.
Target Cross-Reactivity (ELISA)Cross-reaction with human IGF-I is 32%. Cross-reaction with human IGF-II is less than 0.01%.
Target Host SpeciesHuman
Species ReactivityHuman
Immunogen DescriptionRecombinant LR3-IGF1 protein, made in E.coli
Range3.9 ng/mL - 200 ng/mL
SensitivityTypical limit of detection (LOD) for LR_IGF-I is 1 ng/mL determined as 150% of the blank value.
Sample TypeCulture Supernatant
Detection MethodColorimetric
Kit ComponentsThe ELISA kit box contains 96-well pre-coated strip plate(s), protein standards, detection reagents, wash and sample buffers, substrate buffer and detailed protocols.
Storage InstructionsStore at 2-8°C
Storage Temperature2-8°C
Batch NumberPlease see item label.
Expiration Date12 months from purchase.
Alternative NamesHuman LR3 insulin-like Growth Factor-I.
Scientific BackgroundLR_IGF-I is an 83 amino acid analogue of IGF-I comprising the complete human IGF-I sequence with the substitution of an Arginine for the Glutamine at position 3, plus a 13 amino acid extension peptide at the N-terminus.
Shipping StatementFor order quantities larger than 1 plate, this product is supplied in package units of 2 plates.
This standard curve generated in our laboratories is for demonstration purposes only, but can be used as a guide to expected performance. A standard curve should be generated for each assay.